  electrical schematic fig. b ak3d only n' cy g n g' l i n e l f sw c1 r l cy a d c2 o l l' AK1/4 without power sw fig. a ak3/4 only n g i e n f l l sw r c1 l cy n' g' c2 o a d cy l' l component value: 6a: r: 2.2m c1: 0.1uf c2: 0.1uf cy: 3300pf l: 1.3mh  3a: r: 1m c1: 0.1uf c2: 0.1uf cy: 2200pf l: 14mh  for transformers with two separate windings 110v 110v sw l' fig. c r n g i n e l l f c1 l l o a d g' cy cy n' c2 110v 220v 220v 110v 3 4 2 ak series specifications minimum insertion loss in db d v e power entry module emi filters type & rated current 1. power module incorporates an iec connector, a fuse holder with optional power on/off switch and voltage selector switch, plus an emi filter all-in-one single, easy-to-install unit. 2. fuse holder designed for one iec 5x20mm fuse and one spare fuse. safety interlock prevents fuse removal with line plug inserted (use only with 250v fuse). 3. all part numbers are ul recognized, csa certified and vde approved. 1. maximum leakage current each line-to-ground @ 115vac 60hz: 0.25ma @ 250vac 50hz: 0.45ma 2. hipot rating (one minute) line-to-ground: 2250vdc line-to-line: 1450vdc 3. operating frequency: 50/60hz 4. rated voltage: 115/250vac 1. single-pole ul, csa & vde approved current rating: ul & csa-6a both at 125vac & 250vac; vde-6a at 250vac. electrical lifetime: 50,000 cycles. maximum inrush current: 24a. 2. double-pole ul csa & vde approved current rating: ul & csa-6a at 125vac, 4a at 250vac; vde-4a at 250vac. electrical lifetime: 10,000 cycles. maximum inrush current: 51a. 3. voltage selector sw -ul, csa & vde approved current rating: 10a at 125vac; 5a at 250vac. 4. voltage selector sw -ul, csa & vde approved current rating: ul & csa-6a both at 125vac & 250vac; vde-6a at 250vac. delta part no. rated current 115vac 6a 6a 6a 6a 6a 6a 6a 250vac 6a 6a 4a 5a 4a 6a 6a iec connector fuse holder power switch sp dp sp dp voltage selector sw rear rear rear front electrical schematic fig. a fig. a fig. b fig. a fig. b fig. a fig. c AK1 ak2 ak2d ak3 ak3d ak4 ak5 1212 333 4 current frequency-mhz rating .15 .50 1.0 5.0 10 30 3a 30 35 40 35 35 35 6a 16 25 30 42 45 40 3a 10 40 45 45 45 35 6a 6 2530424540 common mode (l-g) in 50 ohm system differential mode (l-l) in 50 ohm system 4-4 introductions
inch mm unit: mechanical construction ak3,ak3d ak4 (without power switch) AK1 ak2,ak2d ak5 1.15 29.2 n l g 2.65 67.3 65.3 2.24 56.9 2.57 26.9 2.17 55.1 1.059 g 2.60 66.0 115v 1.15 29.2 n l g 2.65 67.3 o i 16.5 0.65 26.9 1.059 g 29.2 1.15 n g 2.65 67.3 l 2.24 2.17 56.9 55.1 65.3 2.57 0.43 10.9 0.57 14.48 1.059 26.9 n g l 4 1 3 2 65.3 2.57 60.5 2.38 55.1 2.17 29.2 1.15 n g l o i 67.3 2.65 1.059 26.9 n l g 66.0 1.0 r0.04max. 27.0 2.6 0.003 1.063 0.003 4-5 suggested thickness of mounting panel is from 0.04 to 0.07 inch suggest mounting cutout


▲Up To Search▲   

 
Price & Availability of AK1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X